Overview

The Event Log(System) alarm monitors MSCS errors and warnings output to the event log.

Note that you can use the collection data addition utility to specify the event logs as the target for data collection. For details about the settings required for using the collection data addition utility to collect event log data, see 3.2.3 Settings for collecting event log information.

Reference note
This alarm terminates alarm evaluation when at least one abnormal or warning value is detected. Accordingly, not all collected data is evaluated. Because each log in the event log has specific information that is not related to previous evaluation, we recommend that all collected data be evaluated.
To evaluate all data, copy this alarm and create an alarm with Enable alarm, Always notify, and Evaluate all data selected in the PFM - Web Console alarm properties. Then use this alarm to perform monitoring.

Primary settings

PFM - Web Console alarm property
Settings
Item Detailed item
Basic information Report alarm when the following damping condition is reached. Yes
interval(s) 1
occurrence(s) during 1
Action SNMP Error, Warning, Normal
Condition expression 1 Record Event Log (PD_ELOG)
Field Log Name
Error condition Log Name = System
Warning condition Log Name = System
Condition expression 2 Record Event Log (PD_ELOG)
Field Event Type Name
Error condition Event Type Name = Error
Warning condition Event Type Name = Warning
Condition expression 3 Record Event Log (PD_ELOG)
Field Source Name
Error condition Source Name = ClusSvc
Warning condition Source Name = ClusSvc
Condition expression 4 Record Event Log (PD_ELOG)
Field Event ID
Error condition Event ID <> 0
Warning condition Event ID <> 0
Condition expression 5 Record Event Log (PD_ELOG)
Field Description
Error condition Description <> dummy#
Warning condition Description <> dummy#

#
Set the description of the event log. The value used in the table shows an example of setting a condition value that satisfies the Description field.