16.3 List screen
In the List screen, you can perform tasks such as monitoring units, setting hold attributes, and registering units for execution. Clicking the Dashboard tab displays the Dashboard screen.
You can also open the List screen from the Integrated Operation Viewer window of JP1/IM2.
The following figure shows the List screen.
If automatic refresh is enabled, the List screen is refreshed every 10 minutes, starting from the time that automatic refresh is enabled. The automatic refresh interval can be changed in the Setting dialog box.
The List screen consists of two main areas:
- Tree area
-
This area displays the units the logged-in JP1 user has permission to reference in tree format. When you select a job group in the tree area, the units under the selected job group appear in the list area.
- List area
-
This area displays the units under the job group selected in the tree area.
You can manipulate a unit by selecting it in the list and clicking the buttons above the list. The following table describes the operations that can be performed by using these buttons.
Table 16‒3: Operations that can be performed by clicking the buttons in the List screen No.
Button
Operation
1
Entry#
Displays the Register for Execution dialog box, allowing you to register the selected unit for execution.
2
Leave#
Displays the Cancel Registration dialog box, allowing you to unregister the selected unit for execution.
3
Status
Displays the Monitor dialog box, allowing you to check the current status of the selected unit.
4
Result
Displays the Monitor dialog box, allowing you to check the execution result of the selected unit.
5
Next
Displays the Monitor dialog box, allowing you to check when the selected unit will be executed next.
6
Monthly
Displays the Monthly Schedule screen.
- Cautionary notes
-
-
The List screen can be opened from JP1/IM2 only if the relevant unit or generation exists.
-
If the full name of the target unit contains many multibyte characters, Internet Explorer might not be able to open the List screen from JP1/IM2 because the length of the URL might exceed the browser's upper limit. If Internet Explorer cannot open the List screen, try using Firefox or Google Chrome. If you want to use Firefox or Google Chrome, you will need to set Firefox or Google Chrome as the default browser.
-
If, for a certain length of time, no operations are performed in the List screen and the List screen is not refreshed, the session times out. If the session times out, an error message appears, and the web browser closes. The session timeout period for the Web GUI can be specified by using the environment setting file (ajs3web.conf). The default is 15 minutes. For details about the environment settings file (ajs3web.conf) in Windows, see 3.4.3 Details on the settings in the environment-settings file (ajs3web.conf) in the JP1/Automatic Job Management System 3 Configuration Guide. For details about the environment settings file (ajs3web.conf) in Linux, see 13.3.3 Details on settings in the environment-settings file (ajs3web.conf) in the JP1/Automatic Job Management System 3 Configuration Guide.
-
In Firefox or Google Chrome, the following operations or events that usually cause the web browser to close, instead cause the Login screen being displayed:
- Clicking the Log Out button or the Close button on the Monitor screen.
- An error that usually causes the web browser to close (such as an invalid session error).
-
The Login screen might not be displayed if an error occurs during the startup of the List screen. If the Login screen is not displayed, manually close the web browser.
-
- List of screens that can be displayed from the List screen:
-
No.
Screen
Relevant section
1
Monthly Schedule screen
2
Monitor dialog box
3
Register for Execution dialog box
4
Register Passing Information dialog box
5
Variables Used dialog box
6
Cancel Registration dialog box
7
Setting dialog box
8
Apply Operating Permission Settings dialog box