Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Operator's Guide


16.5 Monthly Schedule screen

On the Monthly Schedule screen, you can check the unit execution schedule on a monthly basis. You can also add and change execution schedules.

The following figure shows the Monthly Schedule screen.

Figure 16‒10: Monthly Schedule screen

[Figure]

The Monthly Schedule screen consists of three main areas:

Tree area

The tree area displays, in a tree layout, the jobnet selected on the Dashboard or List screen and the units under the jobnet.

Schedule area

In the schedule area, you can check monthly unit execution schedules.

The schedule area displays icons that indicate execution schedules. The shape of each icon varies according to the type of execution registration and execution schedule, as follows:

The square : an execution schedule registered for planned execution or immediate execution

The circle : an execution schedule registered for fixed execution

The triangle : an unregistered execution schedule

Each icon appears on the execution day of the corresponding execution schedule. For details about the execution day, see 3.3.1 Time formats and schedule rules for root jobnets in the manual JP1/Automatic Job Management System 3 Overview.

If a unit is executed multiple times in a day (that is, multiple execution generations of the unit exist in the day), only the last execution generation in the day is indicated by an icon.

List area

The list area lists all generations of the execution schedule of the unit selected in the schedule area. Note that this area displays only the execution schedule for the execution day selected in the schedule area.

The start dates and times differ depending on whether execution simulation is performed. If you have configured the system to not perform execution simulation, the start dates and times will differ from those displayed in the Dashboard screen, in which execution simulation is always performed. You can specify whether to perform execution simulation in the Setting dialog box. Jobnets that have never been run are simulated as if they require 1,200 seconds to run.

If you select a unit or execution schedule, and then click a button at the top of the screen, you can perform an operation for the unit or execution schedule. The following table describes the operations that can be performed by using these buttons.

Table 16‒6: Operations that can be performed by clicking the buttons in the Monthly Schedule screen

No.

Button

Operation

1

Entry#1

Displays the Register for Execution dialog box, allowing you to register the selected unit for execution.

2

Leave#1

Displays the Cancel Registration dialog box, allowing you to unregister the selected unit for execution.

3

Hold-On#1

Holds the selected unit.

4

Hold-Off#1

Releases the selected unit from the hold.

5

Add#1

Displays the Add dialog box, in which you can add the selected execution schedule to a specified date and time.

6

Change Plan#1

Displays the following menu commands, which allow you to perform operations such as temporarily changing the selected execution schedule and releasing the execution schedule from the temporary changes:

  • Change Time

    Displays the Change Time dialog box, in which you can change the scheduled start date and time of the execution schedule of the selected unit.

  • Execute Immediately

    Displays the Execute Immediately dialog box, in which you can immediately execute the execution schedule of a selected unit.

  • Execution Prohibited

    Cancels execution of the execution schedule of the selected unit.

  • Release Change

    Releases the execution schedule of the selected unit from temporary changes.

7

Change Delay Monitor#1, #2

Displays the Change Delay Monitor Temporarily dialog box, in which you can change the delay monitoring method for the selected unit.

8

View Delay Monitor#2

Displays the View Temporary Changes to Delay Monitor dialog box, in which you can check the delay monitoring method for the selected unit.

9

Monitor

Displays the Monitor dialog box.

#1

If the operation restriction function of the Web GUI is enabled, these buttons appear only if the logged-in user is a user who is permitted to perform the corresponding operations.

#2

If the operation restriction function of the Web GUI is enabled, when a user who is not permitted to perform the Change Delay Monitor operation logs in, the View Delay Monitor button appears instead of the Change Delay Monitor button.

Cautionary notes

List of screens that can be displayed from the Monthly Schedule screen:

No.

Screen

Relevant section

1

Monitor dialog box

16.6

2

Register for Execution dialog box

16.16

3

Register Passing Information dialog box

16.17

4

Variables Used dialog box

16.18

5

Cancel Registration dialog box

16.19

6

Add dialog box

16.20

7

Change Time dialog box

16.21

8

Execute Immediately dialog box

16.22

9

Change Delay Monitor Temporarily dialog box

16.23

10

View Temporary Changes to Delay Monitor

16.24

11

Change Display Month dialog box

16.25