Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Automatic Operation Administration Guide


13.6  When you cannot connect to the JP1/AO GUI

If you are unable to connect to the JP1/AO GUI, follow the procedure below.

Procedure

  1. Check whether JP1/AO is running as a result of executing the hcmdssrv command with the /status option specified.

  2. If the HAutomation Engine Web Service and HBase Storage Mgmt Common Service are running but the HBase Storage Mgmt Web Service is not, a port number conflict might have occurred. Check the Windows event log.

  3. If the event log contains the following entry, review the port number settings used by the JP1/AO server:

    Table 13‒2: Log entry

    Parameter

    Content

    Level

    Error

    Source

    HitachiWebServer

    Message

    The service named HBase Storage Mgmt Web Service reported the following error:

    >>> (OS 10048)Only one usage of each socket address (protocol/network address/port) is normally permitted. : make_sock: could not bind to address [::]:[duplicate-port-number]