Hitachi

Hitachi Advanced Database Setup and Operation Guide


12.5.2 Steps to take when a failure occurs in the disk containing the audit trail directory

The following explains the steps to take when a failure occurs in the disk containing the audit trail directory.

When a failure occurs in the disk containing the audit trail directory, errno cc....cc is displayed for the variable aa....aa in the KFAA51404-E message. The corrective action to take is as follows.

Action to take

  1. Terminate the HADB server.

    If the HADB server is running, use the adbstop command to terminate the HADB server.

  2. Eliminate the cause of the error.

    Look up the error number displayed in errno cc....cc in the documentation for the operating system, and eliminate the cause of the error.

    If you are unable to eliminate the cause of the error, create a new audit trail directory. After creating the new audit trail directory, specify the path of the new directory in the adb_audit_log_path operand in the server definition.

  3. Start the HADB server.

    Use the adbstart command to start the HADB server.