Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KAVB8817-E

A file specified for a parameter of the communication encryption function for JP1/IM - Manager could not be read. (parameter = parameter-name, parameter value = parameter-value)

A file specified by a parameter of the communication encryption function of JP1/IM - Manager cannot be read.

S:

Stops startup processing of JP1/IM - Manager.

O:

Check the following, and then restart JP1/IM - Manager.

If the problem cannot be resolved, use the data collection tool to collect data, and then contact a system administrator.

  • Check for problems with the format of the file at the path specified by the parameter.

  • Check the appropriate OS log listed in the following to determine if a shortage has occurred in an OS resource such as file descriptors.

    • In Windows: Windows event log

    • In UNIX: System log (syslog)