uCosminexus Application Server, Messages

[Contents][Back][Next]

KFCT73106-W

I/O thread for statistical information service is stopped. ID:aa....aa reason code=bb....bb-cc....cc

aa....aa: Service identifier(CTM identifier)
bb....bb: Reason code
cc....cc: Internal code
Description
The exclusive I/O thread of the statistical information service was stopped.
The acquisition of statistical information cannot continue in the relevant CTM node.
The statistical information service will be suspended in the relevant CTM node.
Action
Based on the list of reason codes described in the following table, remove the cause of the error.

Table 19-17 List of failure reason codes displayed in KFCT73106-W

Reason code Cause Action
1 Memory is insufficient. Revise the memory size
4 The new message queue ID in the msgget system call was not allocated. Delete the unnecessary message queue ID.
11 An attempt to open the statistical information file has failed. Contact maintenance personnel.
12 An I/O error occurred for the statistical information file. Contact maintenance personnel.