uCosminexus Application Server, Messages

[Contents][Back][Next]

KFCT73105-W

failure to create I/O thread for statistical information service. ID:aa....aa reason code=bb....bb-cc....cc

aa....aa: Service identifier(CTM identifier)
bb....bb: Reason code
cc....cc: Internal code
Description
An attempt to create an exclusive I/O thread for the statistical information service has failed.
The statistical information cannot be acquired in the relevant CTM node.
The statistical information service will not be executed in the relevant CTM node.
Action
Based on the list of reason codes described in the following table, remove the cause of the error.

Table 19-16 List of reason codes for errors described in KFCT73105-W

Reason code Cause Action
1 Memory is insufficient. Revise the memory size
3 The shared memory used for operation statistics cannot be accessed. Contact maintenance personnel.
5 The specified environment variable CTMSPOOL is invalid. Revise the value specified in the CTMSPOOL environment variable.
8 The path specified in the environment variable CTMSPOOL is too long. Check whether the length of the path exceeds 1,023 bytes and, if necessary, revise it.
13 An error occurred in the system call. Check the message displayed before this message, and then contact maintenance personnel.