Job Management Partner 1/Performance Management - Agent Option for Platform Description, User's Guide and Reference

[Contents][Glossary][Index][Back][Next]


Committed Mbytes

Overview

The Committed Mbytes alarm monitors the amount of used virtual memory (MB). If the amount of used virtual memory continues to be at or above the threshold (the value of the Total Physical Mem Mbytes field of the PI record), the physical memory area might be insufficient.

Primary settings

PFM - Web Console alarm property
Settings
Item Detailed item
Basic information Report alarm when the following damping condition is reached. Yes
interval(s) 3
occurrence(s) during 2
Action SNMP Error, Warning, Normal
Condition expression Record System Overview (PI)
Field Committed Mbytes
Error condition Committed Mbytes >= 2046#1
Warning condition Committed Mbytes >= 1024#2

#1
Depending on the environment, set a value around 90% of the value of the Commit Limit Mbytes field in the PI record.

#2
Depending on the environment, set the value of the Total Physical Mem Mbyte field in the PI record.

Alarm table

PFM Windows Template Alarms [MEM] 09.00

Related reports

None

[Contents][Back][Next]