Overview
The Committed Mbytes alarm monitors the amount of used virtual memory (MB). If the amount of used virtual memory continues to be at or above the threshold (the value of the Total Physical Mem Mbytes field of the PI record), the physical memory area might be insufficient.
Primary settings
PFM - Web Console alarm property
SettingsItem Detailed item Basic information Report alarm when the following damping condition is reached. Yes interval(s) 3 occurrence(s) during 2 Action SNMP Error, Warning, Normal Condition expression Record System Overview (PI) Field Committed Mbytes Error condition Committed Mbytes >= 2046#1 Warning condition Committed Mbytes >= 1024#2
- #1
- Depending on the environment, set a value around 90% of the value of the Commit Limit Mbytes field in the PI record.
- #2
- Depending on the environment, set the value of the Total Physical Mem Mbyte field in the PI record.
Alarm table
PFM Windows Template Alarms [MEM] 09.00
Related reports
None