Job Management Partner 1/Integrated Management - Manager Quick Reference
After you have finished setting up suppression of automated actions, make sure that the same action does not execute repeatedly.
To make sure that the action does not execute repeatedly:
- Click the OK button in the Action Parameter Detailed Definitions window.
The Action Parameter Definitions window is displayed.
- Click the Apply button in the Action Parameter Definitions window.
The specified settings are updated.
- Using the procedure given in 1.2.2 Verifying that you can execute a command, enter the following settings in the Execute Command window.
On host A, an event of severity level Error is issued.
Item Setting to enter Target host hostA Command jevsend -e SEVERITY=Error
- Repeat step 3.
On host A, an event of severity level Error is issued.
- In 10 minutes, repeat step 3 again.
On host A, an event of severity level Error is issued.
If the automated action was suppressed, an automated action suppression icon (
) is displayed under Action in the events list.
For this example, verify that the following is displayed under Action in the events list.
- The first time the command is executed:
The execution trigger icon is displayed ().
- The second time the command is executed:
The automated action suppression icon is displayed ().
- The third time the command is executed:
Because the ten minutes specified as the suppression time have elapsed, the execution trigger icon is displayed ().
Keywords:
- automated action, generate, severity, time, suppression
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.