17.14.2 Application-related problems (in the case of the cold standby configuration)

If an application-related problem occurs, first take the appropriate corrective action as explained in 15.1 Application-related problems. If this does not resolve the problem, read the information provided in this subsection.

Organization of this subsection

(1) Steps to take when an application cannot be executed

The following table describes the possible reasons why an application cannot be executed and the corrective actions to take.

Table 17‒8: Possible reasons why an application cannot be executed and the corrective actions to take

No.

Possible cause

Action to take

1

The host name of the connection destination might be incorrect.

Check whether a host name is specified that corresponds to the alias IP address used for communication between HADB clients and HADB servers.

Check the locations where the host name of the connection destination for the application is specified, such as the client definition, and correct the host name if necessary.