16.16.3 Command related problems (when the multi-node function is being used)

If a command-related problem occurs, first take the appropriate corrective action as explained in 15.2 Command-related problems. If this does not resolve the problem, read the information provided in this subsection.

Organization of this subsection

(1) Steps to take when a command cannot be executed (when the message KFAA31733-E is output)

If a failure occurs on the master node, recovery processing (rollback) performed on update processing that had been running on the master node, is executed on the slave node that becomes the new master node. If a command accesses any pages undergoing this recovery processing, the command results in an error. At this time, the KFAA31733-E message is output. In this case, follow the steps given in the message.

(2) Steps to take when a command cannot be executed (when the message KFAA50036-E is output)

An attempt was made to execute a command that cannot be executed on a slave node. Execute the command on the master node.