OpenTP1 Version 7 Operation

[Contents][Index][Back][Next]

mcfalstap (Display application timer startup requests)

Format

mcfalstap [-s application-startup-process-identifier] -a application-name

Function

Displays the timer startup requests related to a specified application.

Options

-s application-startup-process-identifier ~<numerals (0-9), a-f> ((01-ef))

Specifies an application startup process identifier. No more than one application startup process identifier can be specified.

If this option is omitted, the mcfalstap command is executed on all MCFs. This means that the overhead required to search for the application startup processes is added to the processing load of the operation commands.

If you want to have a configuration that includes many application startup processes or if you want to use many operation commands, use the -s option to specify an application startup process identifier.

-a application-name~<identifier, 1-8 characters>

Specifies the name of an application whose information is to be displayed.

A maximum of eight application names can be specified. When you enter large number of inputs for the operation, specify more than one application or specify a group of applications, as described below, to increase the number of applications processed in parallel by one command and to reduce the number of commands that are entered.

To specify multiple application names, separate them by a space and enclose the entire string of application names in double quotation marks ("). The same application name cannot be duplicated when specified.

The asterisk (*) can be used in the specification to indicate a group of applications. Only one group can be specified. The name of a group of applications cannot coexist with the names of applications for which no group is specified. A group name must be enclosed in double quotation marks (").

<Example of specifying more than one application>
To specify apl1, apl2, and apl3:
-a "apl1[Figure]apl2[Figure]apl3"

<Example of specifying a group of applications>
To specify all applications with names beginning with apl:
-a "apl*"

Output format

 
mmm aa....aa hh1:mm1:ss1 bbbb hhh2:mm2:ss2
 

Display examples

 
KFCA10360-I Starts TAP status display.
KFCA16436-I A01 ap001    19:06:33 INTV  00:45:00
KFCA16436-I A01 ap2      19:07:17 TIME  19:20:00
KFCA16436-I A01 ap000003 19:08:23 INTV 100:00:00
KFCA10369-I Ends TAP status display.

Output messages

Message ID Description Output destination
KFCA10350-I The mcfalstap command has been entered. Standard output
KFCA10351-E MCF startup processing is underway. Wait for the startup processing to be completed, and then re-enter the command. Standard error output
KFCA10352-E MCF termination processing is underway. Standard error output
KFCA10353-W Input format is invalid. Correct the input format and re-enter the command. Standard error output
KFCA10354-E Memory is inadequate. If the same result occurs when the command is re-entered, check the system environment. Standard error output
KFCA10355-W Specification of an argument is invalid. Check the specification of the application startup process identifier and application names, make corrections, and then re-enter the command. Standard error output
KFCA10356-E Timeout occurred during a process. See the message that was output to a log before this message. Standard error output
KFCA10357-E Timeout occurred in the MCF. See the message that was output to a log before this message. Standard error output
KFCA10358-E Error occurred in an internal function. Standard error output
KFCA10359-W Response to mcfalstap command input source failed. If the reason code is -19178, either do not use a group specification for specifying application names or use a group specification with a leading character string added to narrow the display targets, then re-enter the command. Message log file or standard error output
KFCA10360-I Status display is starting. Standard output
KFCA10369-I Status display is terminating. Standard output
KFCA10372-E The mcfalstap command terminated abnormally. See the message that was output to a log before this message. Standard error output
KFCA10380-E Retrieval of remote a process failed. Check the application startup process identifier and re-enter the command. Standard error output
KFCA10391-E The service for which command execution was attempted does not support the mcfalstap command. Specify the application startup process identifier in the -s option and re-enter the command. Standard error output
KFCA10563-I Help message Standard output
KFCA10714-E Memory is inadequate. If the same result occurs when the command is re-entered, check the system environment. Message log file
KFCA16402-E RPC error occurred during command processing. Take the corrective action indicated by the reason code. Standard error output
KFCA16436-I See the above output format. Standard output
KFCA16437-I No timer startup request has been made, a timer is already active, or an application name is invalid. If this message is output when a timer request exists, make sure that the application name is valid or use a group specification, and then re-enter the command. Standard output