KFCT73202-E
failure to initialize for module trace. reason code=aa....aa-bb....bb
Description
An error occurred while initializing the module trace acquisition used in the performance tracer.
The module trace of the process in which an error occurred is not acquired. This initialization is a preparatory process to acquire the module trace in the process.
Action
Based on the list of reason codes described in the following table, remove the cause of the error, and then reexecute the command.
Reason code |
Cause |
---|---|
101 |
Memory is insufficient. |
106 |
The directory specified in the environment variables PRFSPOOL may not have been created correctly. |
109 |
An error occurred while creating the module trace file. Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E. |
201 |
The following directories cannot be created:
Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E. |
202 |
The following directories cannot be created:
Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E. |
203 |
An error occurred in the umt internal exclusive control. Communicate the errno value of the message KFCT75500-E to our customer service. |
503 |
An attempt to open the directory for creating the module trace file has failed. This directory will be created while starting the PRF daemon. Check whether the PRF daemon is running normally in the execution environment in which this message is displayed. |
505 |
The option argument of the command is invalid. Revise the option argument of the message KFCT73350-E. |
1601 |
A system call error occurred. |