Hitachi

Hitachi Application Server V10 Messages


KFCT73202-E

failure to initialize for module trace. reason code=aa....aa-bb....bb

aa....aa

Reason code

bb....bb

Internal system code

Description

An error occurred while initializing the module trace acquisition used in the performance tracer.

The module trace of the process in which an error occurred is not acquired. This initialization is a preparatory process to acquire the module trace in the process.

Action

Based on the list of reason codes described in the following table, remove the cause of the error, and then reexecute the command.

Reason code

Cause

101

Memory is insufficient.

106

The directory specified in the environment variables PRFSPOOL may not have been created correctly.

109

An error occurred while creating the module trace file.

Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E.

201

The following directories cannot be created:

  • $PRFSPOOL/utt (in UNIX) or %PRFSPOOL%\utt (in Windows)

Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E.

202

The following directories cannot be created:

  • $PRFSPOOL/utt/umt (in UNIX) or %PRFSPOOL%\utt\umt (in Windows)

Remove the cause of the error from the errno value of KFCT73351-E or KFCT75500-E.

203

An error occurred in the umt internal exclusive control.

Communicate the errno value of the message KFCT75500-E to our customer service.

503

An attempt to open the directory for creating the module trace file has failed. This directory will be created while starting the PRF daemon. Check whether the PRF daemon is running normally in the execution environment in which this message is displayed.

505

The option argument of the command is invalid.

Revise the option argument of the message KFCT73350-E.

1601

A system call error occurred.