Hitachi

Hitachi Application Server V10 Messages


KFCT73201-E

module trace cannot be started. reason code=aa....aa-bb....bb

aa....aa

Reason code

bb....bb

Internal system code

Description

An error occurred while starting the module trace acquisition used in the performance tracer.

The module trace will not be acquired.

Action

Based on the list of reason codes described in the following table, remove the cause of the error, and then reexecute the command.

Reason code

Cause

101

Memory is insufficient.

106

The directory specified in the environment variables PRFSPOOL may not have been created correctly.

201

The following directories cannot be created:

  • $PRFSPOOL/utt (in UNIX) or %PRFSPOOL%\utt (in Windows)

202

The following directories cannot be created:

  • $PRFSPOOL/utt/umt (in UNIX) or %PRFSPOOL%\utt\umt (in Windows)

502

An error occurred while creating the necessary environment to control the module trace.

504

An attempt to initialize the timer process has failed. The system continues and the module trace will be acquired. However, the unnecessary files in the following directories will not be deleted:

  • $PRFSPOOL/utt/umt (in UNIX) or %PRFSPOOL%\utt\umt (in Windows)

Normally, the unnecessary files are deleted every 24 hours. Please contact our customer service.

1601

A system call error occurred.