4.3.9 Start Collection window

The Start Collection window sets a collection period and starts collection. The following figure shows the Start Collection window.

Figure 4‒32: Start Collection window

[Figure]

The items to be set are:

Start collection
Immediate

Clicking the Start button starts collection immediately.

Appointed Time

SSO starts collection when the specified date and time are reached. In the Date fields, specify a date between January 1, 1980 and December 31, 2099 in the format yyyy/mm/dd. Specify a time between 00:00:00 and 23:59:59 in the format 00:00:00.

Stop collection
Endless

SSO continues collecting resources until the user instructs it to stop.

Appointed Time

SSO stops collecting resources when the specified date and time are reached.

In the Date fields, specify a date between January 1, 1980 and December 31, 2099 in the format yyyy/mm/dd. Specify a time between 00:00:00 and 23:59:59 in the format 00:00:00. When you have specified a collection start date and time, specify a later date and time for stopping collection.

Appointed Period

SSO stops collecting resources when the specified period has elapsed since collection started.

The specifiable range is 1 minute to 31 days (44,640 minutes). You can specify any value between 1 and 44,640. You can select min, hour, or days as the unit of time.

Statistical threshold initial value calculation setting

Specify settings for calculating the initial value. If multiple collection conditions are selected in the Resource Configuration window, you cannot specify this setting.

Initial value calculation

Select this check box when you want to activate the deactivated list of statistical threshold initial value calculation settings, and the Add, Change, and Delete buttons.

When no information is displayed in the list of statistical threshold initial value calculation settings, the initial value is not calculated.

List of statistical threshold initial value calculation setting

Displays the list of statistical threshold initial value calculation settings you specified in the Initial value calculation setting window. By default, the list is blank.

Add

Displays the Initial value calculation setting window. For details on the Initial value calculation setting window, see 4.3.11 Initial value calculation setting window.

Change

Changes settings selected in the list of statistical threshold initial value calculation settings.

Delete

Deletes settings selected in the list of statistical threshold initial value calculation settings.