4.1.27 Options (Trace) dialog box
The Options dialog box appears when you choose Tools, Options in the Script Manager window.
The Options dialog box has six tabs: Server Information, Compatibility, Multi-activation, JP1/IM, Trace, and Cluster Environment. Click the Trace tab to display the Options (Trace) page.
- Note
-
If you attempt to set up the trace options while the JP1/Script service is not running, a dialog box containing the following error message appears:
The operation could not be performed because the JP1/Script service is not running. Launch the JP1/Script service, and then re-execute the operation.
- Organization of this subsection
(1) Components
- Data items initially allocated in the trace management file
-
Specify the initial data size that can be stored in the trace management file.
Set a value in the range 16 to 32,000. 1,024 is set by default.
(2) Operations
-
Click OK to apply the setting and close the Options dialog box.
-
Click Cancel to close the dialog box without applying the setting.
(3) Processing
-
Changing the initial data size clears the trace management file (SPTLOGDB.SPB). This means that you can no longer view the data previously displayed in the Trace Viewer window. The Script Trace Files Display window may also show incorrect data. If so, close and reopen the Script Trace Files Display window.