Hitachi

JP1 Version 12 JP1/IT Desktop Management 2 Distribution Function Administration Guide


AIT_VerifyState

Organization of this page

Description

Checks whether the specific control has been checked in the active window.

Format

integer AIT_VerifyState  (
  string strCaption,    // Control's caption
  integer nCtrlType     // Control type
);
integer AIT_VerifyState  (
  integer nCtrlID,      // Control ID
  integer nCtrlType     // Control type
);

Parameters

strCaption (input)

Specify the caption of a control.

nCtrlID (input)

Specify a control ID.

nCtrlType (input)

Specify a control type, which must be one of the following values.

Value

Description

CHECKBOX_CTRL

The control type is a check box.

OPTIONBUTTON_CTRL

The control type is an option button.

Return values

The return value is 1 if the control is checked, 0 if not, 2 if unknown, and -1 if the function has not been processed successfully. The unknown status is applied only to CHECKBOX_CTRL. If -1 has been returned, you can use AIT_GetLastError to acquire an extended error code. The following gives the error codes that AIT_GetLastError might return:

Extended error number

Error code

8

ERROR_NOT_ENOUGH_MEMORY

14

ERROR_OUTOFMEMORY

87

ERROR_INVALID_PARAMETER

112

ERROR_DISK_FULL

1400

ERROR_INVALID_WINDOW_HANDLE

1460

ERROR_TIMEOUT

Note

You can identify the control by using a complete caption or an associated label name or specifying the first part of such a caption or label name. When specifying the first part, prefix a swung dash (~) to the character string that you specify.