Overview

The Service Stop alarm monitors the service name used in the service control manager database and the service status at the time of data collection. If the application service (process) is not active (running), it means that the service has stopped.

Main settings

Table 6‒18: PFM - Web Console alarm property setting (Service Stop)

Alarm properties in PFM - Web Console

Setting

Item

Details

Main Information

Product

RM Platform

Alarm message

State of service(%CVS1) has changed

Enable alarm

Selected

Alarm notification

Notify when the state changed

Notification target

State changes for the alarm

Evaluate all data

Do not specify.

Monitoring time range

Always monitor

Report alarm when the following damping condition is reached

Do not specify.

occurrence(s) during

0

interval(s)

0

Alarm Conditions

Record

Application Service Overview (PD_ASVC)

Field

  • Service Name

  • State

Abnormal condition

Service Name = JP1PCAGT_7S_RM#

AND State <> Running

Warning condition

Service Name = JP1PCAGT_7S_RM#

AND State <> Running

Actions

Email

--

Command

--

SNMP

Abnormal, Warning, Normal

Legend:

--: The setting is always ignored.

#

Specify the name of the service to be monitored. The settings in the table gives an example that sets the service name for a Remote Monitor Store service whose instance name is RM. Make sure that the character string you enter matches what is entered in the Service Name field of the PD_ASVC record.

Any character in the information to be acquired that is not in the ASCII character set range of 0x20 to 0x7E will be converted to a hash mark (#: 0x23) before it is stored in the Service Name field of the PD_ASVC record. Note that multi-byte characters are processed in single-byte units during conversion. For example, the multi-byte (full-width) letter [Figure] is converted as follows:

Information to be acquired

Information after conversion

Character encoding

Binary

Binary

Character string

Shift-JIS

8260

2360

#`

EUC

A3C1

2323

##

UTF-8

EFBCA1

232323

###

Alarm table

PFM RM Platform Template Alarms [SVC] 09.10

Related reports

None.

Note