Hitachi

JP1 Version 12 JP1/Performance Management - Remote Monitor for Platform Description, User's Guide and Reference


Page Faults

Organization of this page

Overview

The Page Faults alarm monitors the memory load status.

Main settings

Table 6‒13: Alarm property settings in PFM - Web Console (Page Faults)

Alarm properties in PFM - Web Console

Setting

Item

Details

Main Information

Product

RM Platform

Alarm message

Page fault is %CVS/sec

Enable alarm

Selected

Alarm notification

Notify when the state changed

Notification target

State changes for the alarm

Evaluate all data

Do not specify.

Monitoring time range

Always monitor

Report alarm when the following damping condition is reached

Selected

occurrence(s) during

2

interval(s)

3

Alarm Conditions

Record

System Summary (PI)

Field

Page Fault Counts/sec

Abnormal condition

Page Fault Counts/sec >= 5

Warning condition

Page Fault Counts/sec >= 4

Actions

Email

--

Command

--

SNMP

Abnormal, Warning, Normal

Legend:

--: The setting is always ignored.

Alarm table

PFM RM Platform Template Alarms 10.00

Related reports

Reports/RM Platform/Troubleshooting/Real-Time/System Overview

Note

Do not use this alarm when the OS of the monitored host is HP-UX or Linux.