Network Received
- Organization of this page
Overview
The Network Received alarm monitors for reception of data that exceeds the bandwidth of the network interface card.
Main settings
Alarm properties in PFM - Web Console |
Setting |
|
---|---|---|
Item |
Details |
|
Main Information |
Product |
RM Platform |
Alarm message |
Received is %CVS bytes/sec |
|
Enable alarm |
Selected |
|
Alarm notification |
Notify when the state changed |
|
Notification target |
State changes for the alarm |
|
Evaluate all data |
Do not specify. |
|
Monitoring time range |
Always monitor |
|
Report alarm when the following damping condition is reached |
Selected |
|
occurrence(s) during |
3 |
|
interval(s) |
5 |
|
Alarm Conditions |
Record |
Network Interface Overview (PI_NET) |
Field |
Rcvd Bytes/sec |
|
Abnormal condition |
Rcvd Bytes/sec >= 50000#1 |
|
Warning condition |
Rcvd Bytes/sec >= 50000#2 |
|
Actions |
|
-- |
Command |
-- |
|
SNMP |
Abnormal, Warning, Normal |
- Legend:
-
--: The setting is always ignored.
- #1
-
A guideline for the value to be set is about 70% of the NIC bandwidth.
- #2
-
A guideline for the value to be set is about 50% of the NIC bandwidth.
Alarm table
PFM RM Platform Template Alarms 10.00
Related reports
Reports/RM Platform/Troubleshooting/Real-Time/Network Data
- Note
-
-
Do not use this alarm when the OS of the monitored host is UNIX.
-
50000 is set as the value for this alarm for both abnormal and warning conditions. To use this alarm, change the values for abnormal and warning conditions as appropriate to the user's environment.
-