Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KAJV2301-W

A JP1 event (event ID = event-ID, serial number in the event database = serial-number-in-event-database) could not be correlated because the correlation event generation condition (correlation-event-generation-condition-name) has already correlated maximum-number pairs of JP1 events.

A single correlation condition can correlate multiple pairs of JP1 events up to the number of simultaneous correlations specified (CORRELATION_NUM; if not specified, 10).

Generation processing could not be performed on the received JP1 event because the generating condition displayed in the message is already correlating maximum-number pairs of JP1 events.

S:

Continues processing.

O:

Carefully review the generating conditions.

  • Determine whether an unnecessarily long time-out time was specified.

  • Determine whether the combination of event conditions is valid.