Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Messages


KAJV2156-E

An attempt to initialize communication processing for the correlation event generation service has failed. (IP address = IP-address, port number = port-number, reason = reason)

An attempt to initialize communication processing for event generation function failed.

S:

When multiple LANs are set up, the system ignores the IP address that generated the error and continues processing.

When there is a single LAN, the system terminates event generation function.

O:

Make sure that the port number of the service name jp1imegs defined in the services file is not being used by another service.

If the port number is duplicated, specify a unique port number.

Also check the OS settings and log to make sure that the network is available.

If the cause is other than the above, use the data collection tool to collect data, and then contact a system administrator.