Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT0025-E

The last registered contents cannot be recovered because the processing to recover consistency failed.(maintenance-information)

The system cannot resume the monitoring of the jobnet with start conditions or the event job that was being monitored when the event/action control manager was stopped last time.

(S)

Places the previously registered jobnet with start conditions in the Monitor terminated status or places the event job in the Unknown end status status, and then start the event/action control manager.

(O)

Check the following:

  • Check whether the system resources are sufficient. Especially, check whether there was sufficient space on the disk containing the directory for output of the wait information file during JP1/AJS3 operation.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether the directory created during installation of JP1/AJS3 was deleted inadvertently.

Because the wait information file might have been corrupted, cold-start JP1/AJS3.