KAVT0023-E
An error occurred during processing of a request to monitor event icons. (maintenance-information) (AjsServiceName=scheduler-service-name, UnitID=unit-ID, ExecID=execution-ID, maintenance-information)
An error occurred while event job monitoring was starting.
- (S)
-
Terminates the event job in the Failed to start status.
- (O)
-
Check the following, and then use the ajsname command with the -I option to identify the job name from the unit ID. Retry operation on the identified event job:
-
Check whether the system resources are sufficient. Especially, check whether there is sufficient space on the disk that contains the directory for output of the wait information file.
-
Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.
-
Check whether the directory created during installation of JP1/AJS3 was deleted inadvertently.
-
Check whether the target host and JP1/AJS3 have started.
-