Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Command Reference


5.2.22 Local power control job definition

This paragraph explains how to specify definition for a local power control job.

The following gives the format of, and the parameters for a local power control job definition.

Format
[pwlt={f|r|s};]
[pwlf={m|r|f|p};]
[pfm={u|p};]
[etm=n;]
[fd=time-required-for-execution;]
[ex="execution-agent-name";]
[ha={y|n};]
[eu={ent|def};]
[jty={q|n};]
[mm={and|or};]
[nmg={y|n};]
[eun=name-of-the-unit-whose-end-is-being-waited-for;]
[ega={exec|execdeffer|none};]
[uem={y|n};]
Parameters
pwlt={f|r|s};

Define the type of execution. The default is f.

  • f: Turns off power. The JP1/AJS3 host will then be started at the time specified in JP1/AJS3 - Manager. For details, see the manual JP1/Power Monitor Description, User's Guide and Reference.

  • r: Shuts down, then restarts the local power supply.

  • s: Shuts down the local power supply. (You can specify this only with pfm=p; set.)

pwlf={m|r|f|p};

Define the type of termination request. The default is f.

  • m: (You can specify this only with pfm=u; set.)

  • r: Restrictive termination. (You can specify this only with pfm=u; set.)

  • f: Kill

  • p: Planned termination. (You can specify this only with pfm=p; set.)

pfm={u|p};

Define a platform type for job execution. The default is p.

  • u: UNIX environment

  • p: Windows environment

etm=n;

Define the time-out period using the relative minutes from the start time. You can set 1 to 1,440 minutes.

fd=time-required-for-execution;

Define the time-required-for-execution within which the job is expected to be terminated.

You can specify a decimal value between 1 and 1,440 (minutes).

ex="execution-agent-name";

Define the name of the execution agent or execution agent group that is used to execute jobs.

You can set a character string of 1 to 255 bytes.

If you want to use a double quotation mark (") or a hash mark (#) as a character, prefix the character with #. That is, use #" instead of ", and use ## instead of #.

If the job has the queuing attribute (jty=q), you can specify a macro variable.

ha={y|n};

Define whether to suspend job execution. The default is n.

  • y: Suspends jobnet execution.

  • n: Does not suspend jobnet execution.

eu={ent|def};

Define the JP1 user who executes the job. The default is ent.

  • ent: The JP1 user who registered the jobnet executes the job.

  • def: The JP1 user who owns the job executes the job.

jty={q|n};

Define the queuing attribute type. If you do not specify this option, q is assumed.

  • q: The queuing attribute exists.

  • n: The queuing attribute does not exist.

mm={and|or};

Define the wait method with respect to the specified units whose ends are being waited for.

The default is and.

  • and: Start executing at completion of all units whose ends are being waited for.

  • or: Start executing at completion of one of the units whose ends are being waited for.

nmg={y|n};

Define the behavior when there are no generations of the root jobnet for the specified unit whose end is being waited for.

The default is n.

  • y: Start executing.

  • n: Do not start executing.

eun=name-of-the-unit-whose-end-is-being-waited-for;

Define the full-path name of a unit whose end is being waited for.

To specify multiple units, repeat the parameter. You can specify a maximum of 32 units.

You can use a character string of 1 to 930 bytes as the unit name.

ega={exec|execdeffer|none};

Specify the behavior when a jobnet with start conditions is specified as the jobnet whose end is being waited for and the execution generation ends abnormally.

If you omit this option, the system assumes none.

  • exec: Start executing.

  • execdeffer: Do not start executing. However, if the execution generation is in the Skipped so not exe. status, start executing.

  • none: Do not start executing.

uem={y|n};

Specify the behavior when a jobnet with start conditions is specified as the jobnet whose end is being waited for and the monitoring generation is in the Unmonitored + Ended status.

If you omit this option, the system assumes n.

  • y: Start executing.

  • n: Do not start executing.