Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Command Reference


5.2.21 OpenView Status Report job definition

This paragraph explains how to specify an OpenView Status Report job definition.

The following gives the format of, and the parameters for an OpenView Status Report job definition.

Format
[cmsts={un|no|wa|mi|ma|cr|re|te|di};]
[cmaif="additional-information";]
[pfm={u|p};]
[etm=n;]
[fd=time-required-for-execution;]
[ex="execution-agent-name";]
[ha={y|n};]
[eu={ent|def};]
[jty={q|n};]
[mm={and|or};]
[nmg={y|n};]
[eun=name-of-the-unit-whose-end-is-being-waited-for;]
[ega={exec|execdeffer|none};]
[uem={y|n};]
Parameters
cmsts={un|no|wa|mi|ma|cr|re|te|di};

Define the status to be reported to HP NNM. The default is un.

  • un: Unknown

  • no: Normal

  • wa: Warning

  • mi: Minor

  • ma: Major

  • cr: Critical

  • re: Restricted

  • te: Testing

  • di: Disabled

cmaif="additional-information";

Define additional information about a message to be reported to HP NNM.

You can set a character string of 1 to 256 bytes. Note that you cannot use a carriage-return character.

If you want to use a double quotation mark (") or a hash mark (#) as a character, prefix the character by #. That is, use #" instead of " and use ## instead of #.

You can specify a macro variable.

pfm={u|p};

Define a platform type for job execution. The default is p.

  • u: UNIX environment

  • p: Windows environment

etm=n;

Define the time-out period using the relative minutes from the start time. You can set 1 to 1,440 minutes.

fd=time-required-for-execution;

Define the time-required-for-execution within which the job is expected to be terminated.

You can specify a decimal value between 1 and 1,440 (minutes).

ex="execution-agent-name";

Define the name of the execution agent or execution agent group that is used to execute jobs.

You can set a character string of 1 to 255 bytes.

If you want to use a double quotation mark (") or a hash mark (#) as a character, prefix the character with #. That is, use #" instead of ", and use ## instead of #.

If the job has the queuing attribute (jty=q), you can specify a macro variable.

ha={y|n};

Define whether to suspend job execution. The default is n.

  • y: Suspends jobnet execution.

  • n: Does not suspend jobnet execution.

eu={ent|def};

Define the JP1 user who executes the job. The default is ent.

  • ent: The JP1 user who registered the jobnet executes the job.

  • def: The JP1 user who owns the job executes the job.

jty={q|n};

Define the queuing attribute type. If you do not specify this option, q is assumed.

  • q: The queuing attribute exists.

  • n: The queuing attribute does not exist.

mm={and|or};

Define the wait method with respect to the specified units whose ends are being waited for.

The default is and.

  • and: Start executing at completion of all units whose ends are being waited for.

  • or: Start executing at completion of one of the units whose ends are being waited for.

nmg={y|n};

Define the behavior when there are no generations of the root jobnet for the specified unit whose end is being waited for.

The default is n.

  • y: Start executing.

  • n: Do not start executing.

eun=name-of-the-unit-whose-end-is-being-waited-for;

Define the full-path name of a unit whose end is being waited for.

To specify multiple units, repeat the parameter. You can specify a maximum of 32 units.

You can use a character string of 1 to 930 bytes as the unit name.

ega={exec|execdeffer|none};

Specify the behavior when a jobnet with start conditions is specified as the jobnet whose end is being waited for and the execution generation ends abnormally.

If you omit this option, the system assumes none.

  • exec: Start executing.

  • execdeffer: Do not start executing. However, if the execution generation is in the Skipped so not exe. status, start executing.

  • none: Do not start executing.

uem={y|n};

Specify the behavior when a jobnet with start conditions is specified as the jobnet whose end is being waited for and the monitoring generation is in the Unmonitored + Ended status.

If you omit this option, the system assumes n.

  • y: Start executing.

  • n: Do not start executing.