Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Operator's Guide


11.4.7 Preventing unit selection and the scroll position from being maintained after the window is updated or list filtering is specified

You can prevent JP1/AJS3 - View from keeping the same units selected and maintaining the same scroll position when you select Refresh in the JP1/AJS3 - View window or specify list filtering.

Specify from:

JP1/AJS3 - View file (User-specified option file)

For details, see 11.1.1 Types of customization methods.

Specification

Use the following format:

jajsKeepSelectAndScrollAfterRefresh={Yes|No} (return)

Specify No if you do not want to keep the same units selected and maintain the same scroll position after you refresh the screen or apply a list filter. Specify Yes to keep the same units selected and maintain the same scroll position.

The default is Yes. If you omit this setting, Yes is assumed.

Example

To prevent JP1/AJS3 - View from keeping the same units selected and maintaining the same scroll position when you refresh the window contents or specify list filtering:

jajsKeepSelectAndScrollAfterRefresh=No (return)