Hitachi

JP1 Version 12 JP1/Navigation Platform Content Editing Guide


5.5.2 How to use Automatic Operation Property Output Plugin parts

  1. Place an Automatic Operation Service Execution Plugin on the node where the JP1/AO service will run.

  2. In the node next from the node where the Automatic Operation Service Execution Plugin is placed, place an Automatic Operation Window URL Creation Plugin for confirming the task status.

  3. When executing content, wait for the task status to change to Completed before advancing to the next node.

  4. In the next node from the node where the Automatic Operation Window URL Creation Plugin is placed, place an Automatic Operation Property Output Plugin and use Guide Parts to connect it with the output parameters whose properties you want to output.

Important
  • The properties that are output by this plugin are for the service that was executed most recently by an Automatic Operation Service Execution Plugin.

  • In Operational Content where an Automatic Operation Service Execution Plugin is executed multiple times, design the Operational Flow so that the flow cannot return to a previous step. If the flow can return to a previous step, the plugin might output properties for the wrong task.

  • This plugin cannot output properties whose data type is composite. If composite data is output, the Guide Parts might not be displayed correctly.

  • If this plugin outputs a property that does not exist in the task or a property whose data type is password, the cached value for the connected Guide Parts is not updated. For details about the cached value of Guide Parts, see the manual JP1/Navigation Platform Development Guide.

  • This plugin outputs (\r\n) and (\n) contained in the property values acquired from an Automatic Operation as a linefeed code (\r\n).