Hitachi

JP1 Version 12 JP1/Navigation Platform Setup and Operations Guide


C.2 Limit values during Navigation Platform operation

The following table lists and describes the limit values that are applicable to operation of Navigation Platform.

Table C‒2: Limit values during Navigation Platform operation

No.

Item

Limit value

1

Maximum number of users who can log in to Navigation Platform concurrently (maximum number of users per server)

300 users

2

Maximum number of users who can run Navigation Platform concurrently

10 users

3

Maximum number of Operational Contents that can be created

500#1

4

Maximum length of a user ID used to log in to Navigation Platform

31 bytes#2

5

Maximum length of a name for a group to which a user logging in to Navigation Platform belongs (when using a directory server for user authentication)

64 bytes

6

Maximum length of a display name for a user logging in to Navigation Platform (when using a directory server for user authentication)

255 bytes

7

Maximum number of links that can be displayed in the link1 to link9 menus in the header area in the Operational Content Execution Window

9

#1

You can use the ucnp.base.client.menu.maxnum property to change this value within the range from 1 to 2,000. For details, see 5.11 Procedure for increasing the maximum number of Operational Contents.

#2

Only single-byte alphanumeric characters are permitted.