Hitachi

JP1 Version 12 JP1/Automatic Operation Messages


KNAE08128-E

Cannot connect to the destination host (connection target: {0}).

[Cause]

Possible causes are as follows:

(1) The destination host was rebooted during the connection.

(2) A process that this product started on the destination host was stopped.

(3) The values specified for wmi.adapter.id in the following properties files are the same in the same cluster: (i) the destination property file for connecting to a physical host, and (ii) the destination property file for connecting to a logical host.

(4) The values specified for wmi.adapter.id in the destination property files are the same in the another product.

[Action]

Check the start status of the destination host, and then re-execute the service. If the destination host is a Windows cluster system, specify different values for the wmi.adapter.id value in the destination property file for the physical host and logical host on the same cluster system. If the destination host is a Windows host, check that the value of wmi.adapter.id in the destination property file does not match that of the another product. If the problem persists, collect log information, and then contact your system administrator.

0: Host name or IP address of the destination host