2.3.4 Notes about installing (for UNIX)
-
Relationship between products
JP1/IM - Manager requires JP1/Base. When you install the products, note the following:
-
Any prerequisite products must be installed first and in the correct order.
Install JP1/Base and then JP1/IM - Manager, in this order.
-
Stop JP1/Base before you install JP1/IM - Manager. If you forgot to stop JP1/Base, make sure that you restart JP1/Base. If you do not restart JP1/Base, it will not be possible to manage system configuration information correctly.
-
-
About Hitachi Network Objectplaza Trace Library (HNTRLib2)
-
When you install JP1/Base, Hitachi Network Objectplaza Trace Library (HNTRLib2) is installed.
-
-
Settings in the OS environment
-
During installation, the following information is set in the OS:
In the services file, the port numbers indicated in Appendix C. Port Numbers in the JP1/Integrated Management - Manager Overview and System Design Guide are set.
-
During uninstallation of JP1/IM - Manager, the port numbers indicated in Appendix C. Port Numbers in the JP1/Integrated Management - Manager Overview and System Design Guide are deleted.
-
-
About downgrade installation
JP1/IM - Manager does not support downgrade installation. If you want to downgrade the product that has been installed, uninstall the product, and then reinstall it.