Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/IT Desktop Management 2 - Smart Device Manager Description, User's Guide, Reference and Operator's Guide


12.3 Changing the connection destination port number for the database

You can change the connection destination port number for the database on the smart device manager.

Prerequisites

You must stop all the JP1/ITDM2 - SDM program modules and all commands.

Procedure

  1. On the communication server, stop the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager (Communication Server Service)

  2. On the smart device manager, start the command prompt, and then change the current directory to the command storage location.

  3. On the smart device manager, execute the sdmnetchange command.

  4. On the smart device manager, use a text editor to open the following file:

    JP1/ITDM2 - SDM (Smart Device Manager)-installation-folder\db\conf\pdsys

  5. Change the value of pd_name_port.

    Example: Change the underlined part:

    set pd_name_port = 26066
  6. On the smart device manager, stop the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager Server Service

  7. On the smart device manager, stop the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager (DB Service)

  8. On the smart device manager, start the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager (DB Service)

  9. On the smart device manager, start the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager Server Service

  10. On the communication server, start the following service from the Windows Services window:

    JP1/ITDM2 - Smart Device Manager (Communication Server Service)

Result

The connection destination port number for the database is changed.

Related topics