Job Management Partner 1 Version 10, Job Management Partner 1/Performance Management - Agent Option for Platform Description, User's Guide and Reference
Overview
The Committed Mbytes alarm monitors the amount of used virtual memory (MB). If the amount of used virtual memory continues to be at or above the threshold (the value of the Total Physical Mem Mbytes field of the PI record), the physical memory area might be insufficient.
Primary settings
| PFM - Web Console alarm property | Settings | |
|---|---|---|
| Item | Detailed item | |
| Main Information | Product | Windows |
| Alarm message | Committed Mbytes = %CVS1 | |
| Enable alarm | Yes | |
| Monitoring time range | Evaluate regularly | |
| Evaluate all data | No | |
| Report alarm when the following damping condition is reached. | Yes | |
| interval(s) | 3 | |
| occurrence(s) during | 2 | |
| Action | -- | |
| Command | -- | |
| SNMP | Abnormal, Warning, Normal | |
| Alarm Conditions | Record | System Overview (PI) |
| Field | Committed Mbytes | |
| Abnormal condition | Committed Mbytes >= 2046#1 | |
| Warning condition | Committed Mbytes >= 1024#2 | |
Alarm table
PFM Windows Template Alarms [MEM] 09.00
Related reports
None
All Rights Reserved. Copyright (C) 2013, Hitachi, Ltd.