6.4.11 Importing alarm tables
-
Log on to PFM - Web Console from the Web browser of the monitoring console.
-
In the navigation frame of the main window, select the Alarms tab.
-
In the method frame of the Alarms window, select the Import method.
-
In the Import window, click the Browse button beside Import file name.
The operating system displays a dialog box in which you can choose a file. Select the definition file of the alarm to be imported. The root, folders, and alarm tables described in the definition file to be selected here are imported. When you select a file, a confirmation message box appears.
-
If you want to replace the definition file of the alarm table, click the OK button in the message box.
The alarm tables are imported.
- Note:
-
-
If importing an alarm table causes one of the already bound alarm tables to be overwritten, the alarm table is unbound. You must rebind the alarm table, if necessary.
-
When you import an alarm table to PFM - Manager which does not support monitoring of operating status for each instance, the alarms in alarm table are imported as alarms for which State changes for the alarm is selected.
-