Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Performance Management User's Guide


4.2.1 Changing the maximum number of records for event data

In the Services window of PFM - Web Console, you can change the number of event data records that the Store database can store for each agent or Remote Monitor Collector service.

Note:

You need to have Administrator user permissions to use the Services window.

  1. Log on to PFM - Web Console from the Web browser of the monitoring console.

    You need to log on as a user with Administrator user permissions.

  2. In the navigation frame of main window, select the Services tab.

  3. In the navigation frame of the Services window, expand the hierarchy under the PFM - Manager folder.

    Services provided by PFM - Manager are displayed. The name of each service is represented by the service ID.

  4. Select the Master Store service.

    The name of the Master Store service begins with PS or is <Master Store>.

    The selected Master Store service is marked with a checkmark.

  5. In the method frame, select Properties.

  6. In the Properties window for the Master Store service, select the Retention node from the tree.

    At the bottom of the information frame, the properties of the Retention node are displayed.

    Modify the property settings. The following table gives a description and setting for the property.

    Table 4‒20: Description and settings for each property

    Record type

    Property name

    Settings

    PA record type

    Product Alarm - PA

    Sets the maximum number of event data records to store for each agent or Remote Monitor Collector service. You can specify a numerical value from 0 to 2,147,483,647.#

    #

    For details on how to estimate the maximum number of records to retain, see the section on disk usage in the appendixes of the Job Management Partner 1/Performance Management Planning and Configuration Guide.

  7. Click Finish or Apply.

    Your settings are enabled.