A.2 Displaying PFM - Web Console

Organization of this subsection

(1) Number of View Report windows displayable in PFM - Web Console

The following table describes the estimated number of View Report windows displayable in PFM - Web Console.

Table A‒1: The number of View Report windows displayable in PFM - Web Console

Contents

Recommended number

View Report windows displayable in a single PFM - Web Console

4

View Report windows that can display information on a single PFM - Agent or PFM - RM in multiple PFM - Web Consoles

10

(2) Maximum number of data items displayed in a report

In real-time reports, data from a maximum of 30 collection times can be displayed. To change the maximum number of data items displayed in a report, change maxRealtimeCache in the initialization file (config.xml).

(3) Number of displayed real-time reports

If multi-instance records are collected in PFM - Agent or PFM - RM, the maximum number of instances handled by a collection is 32,767.

(4) Number of fields displayed in a report

Although there are no restrictions on the number of fields in a report, the system might be unable to display the graph or legend in part or in its entirety when the report contains too many fields. We recommend that you set about 20 fields per report.

(5) Number of tiled charts displayed

By default, a report can display a maximum of fifty tiled charts. If tiling charts puts a heavy load on the server, separate the target bookmark into multiple bookmarks to reduce the number of charts to be displayed.

If you want to change the maximum number of tiled charts for a report, modify the maxTileReports value in the initialization file (config.xml).

(6) Number of user accounts that can log in concurrently