1.3.3 Linkage with AS/400 (JP1/OJE for Midrange Computer)
- Limit values
-
You can use the following commands for the AS/400 system:
jpqendjobshow, jpqjobcan, jpqjobget, jpqjobshow, jpqjobsub, jpqqueshow and ajsdefine (QUEUE job definition information in a unit definition file).
The following table lists the limit values for the commands.
Table 1‒5: Limit values when linking with AS/400 (JP1/OJE for Midrange Computer)
Defined Item
|
Limit values
|
Manager host name
|
Host name for the AS/400 system: Character string of up to 15 bytes.
|
Queue name
|
Job queue name for the AS/400 system: Character string of up to 10 bytes.
|
Job name
|
Job name for the AS/400 system: Character string of up to 10 bytes.
The default is NONAME.
|
User name
|
Character string of up to 32 bytes.
Japanese characters cannot be specified.
|
Execution priority
|
Specify the execution priority for the job on the AS/400 system. You can set 1, 3, or 5.
The highest priority is 5. By default, the system assumes 1. If you specify 2 or 4, the system assumes 1 or 5, respectively.
|
Execution file name
|
Specify the name of the executable file on the AS/400 system in library-name/file-name or library-name/file-name.member-name format. For each part of the name, you can specify a character string of up to 10 bytes.
|
Parameter
|
Specify a parameter string of up to 32 bytes that you want to pass to the executable file on the AS/400 system. You can specify
more than one parameter by delimiting them with a comma.
|
Transfer source file name
|
Specify a file in JP1/AJS3 - Manager. Use a character string of up to 511 bytes. Specify a full-path file name. Only plain-text
files can be transferred. Each line cannot exceed 80 characters.
|
Transfer destination file name
|
Specify the destination on the AS/400 system in library-name/file-name.member-name format. You must specify a file which already exists on the AS/400 system. If you specify the file in file-name.member-name format without a library name, the system assumes the library name specified with DFT_PTH in the configuration definition file for the AS/400 system.
|
For further details, see the Job Management Partner 1/Open Job Entry for Midrange Computer Description and User's Guide.
To Page Top