15.12.1 Configuration of the window
The following figure shows the Wait Conditions Statuses window.
Figure 15-212 Wait Conditions Statuses window
![[Figure]](FIGURE/ZV142186.GIF)
The following explains the displayed items.
- Name
- Displays the icon and unit name of the unit with wait conditions.
- Upper path
- Displays the path for the upper-level unit of the unit with wait conditions including the scheduler service name.
- Comment
- Displays the comment defined for the unit with wait conditions.
- Status
- Displays the status of the unit with wait conditions.
- If the unit with wait conditions is a jobnet with a start condition, this item displays the status of the monitoring generation.
- Execution ID
- Displays the execution ID of the unit with wait conditions.
- If the unit with wait conditions is a jobnet with a start condition, this item displays the execution ID of the monitoring generation.
- Waiting-target unit
- Displays the icon and unit name of the unit whose end is to be waited for by the unit with wait conditions.
- A question mark (?) is displayed as the icon if you do not have reference permission for the unit whose end is being waited for or its upper-level unit.
- No icon appears if any of the following apply:
- The definition of the unit whose end is to be waited for is invalid
- The unit whose end is to be waited for is not scheduled for execution
- The unit whose end is to be waited for is not registered
- Upper path(waiting-target)
- Displays the path for the upper-level unit of the unit whose end is being waited for, including the scheduler service name.
- Comment(waiting-target)
- Displays the comment defined for the unit whose end is being waited for.
- If the target of the wait condition is a planning group, this column displays the comment of the unit in the planning group whose end is actually being waited for.
- A hyphen (-) appears in this column when:
- The definition of the unit whose end is being waited for is invalid
- The unit whose end is being waited for is not scheduled for execution
- The unit whose end is being waited for is not registered
- You do not have reference permission for the unit whose end is being waited for or its upper-level unit
- The target of the wait condition is a planning group, and the unit in the planning group whose end is actually being waited for is not scheduled for execution
- Status(waiting-target)
- Displays the status of the unit whose end is being waited for.
- If the unit whose end is being waited for is a jobnet with a start condition, this item displays the status of the monitoring generation.
- If the unit whose end is being waited for is a planning group, this item displays the status of the unit under the planning group.
- A hyphen (-) appears in this column when:
- The definition of the unit whose end is being waited for is invalid
- The unit whose end is being waited for is not scheduled for execution
- The target of the wait condition is a planning group, and the unit in the planning group whose end is actually being waited for is not scheduled for execution
- Not registered appears in this column if the unit whose end is being waited for has not been registered for execution.
- This information appears even if you do not have reference permission for the unit whose end is being waited for or its upper-level unit.
- Execution ID(waiting-target)
- Displays the execution ID of the unit whose end is being waited for.
- If the unit whose end is being waited for is a jobnet with a start condition, this item displays the execution ID of the monitoring generation.
- If the unit whose end is being waited for is a planning group, this item displays the execution ID of the unit under the planning group.
- A hyphen (-) appears in this column when:
- The definition of the unit whose end is being waited for is invalid
- The unit whose end is being waited for is not scheduled for execution
- The target of the wait condition is a planning group, and the unit in the planning group whose end is actually being waited for is not scheduled for execution
- This column is blank if the unit whose end is being waited for has not been registered for execution.
- This information appears even if you do not have reference permission for the unit whose end is being waited for or its upper-level unit.
- Waiting status
- Displays the wait status with respect to the unit whose end is being waited for, as one of the following:
- Wait incomplete
The end of the waiting-target unit is still being waited for.
- Wait incomplete (manual)
The end of the waiting-target unit is still being waited for, as a result of manual reinstatement of the wait condition.
- Wait complete
The waiting-target unit has finished executing and is no longer being waited for.
- Wait complete (manual)
The end of the waiting-target unit is no longer being waited for, as a result of manual deactivation of the wait condition.
- Wait method
- Displays the wait method as specified in the Waiting Condition Settings dialog box.
- If not waiting for any generations
- Displays the behavior when there are no applicable generations of units whose ends are being waited for, as specified in the Waiting Condition Settings dialog box.
- When Unmonitored + Ended
- Displays the behavior when the unit whose end is being waited for is a jobnet with a start condition, as specified in the Waiting Condition Settings dialog box.
- A hyphen (-) appears in this column when:
- You connect to JP1/AJS3 - Manager version 09-50 from JP1/AJS3 - View version 10-00 or later
- Abnormal end for an execution generation
- Displays the behavior when the unit whose end is being waited for is a jobnet with a start condition, as specified in the Waiting Condition Settings dialog box.
- The Start when skipped so not exe. setting is not displayed.
- A hyphen (-) appears in this column when:
- You connect to JP1/AJS3 - Manager version 09-50 from JP1/AJS3 - View version 10-00 or later
Copyright (C) 2012, Hitachi, Ltd.