Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Integrated Management - Manager Configuration Guide


5.7.1 Setting for the maximum number of status change events

A JP1 warning-level event can be issued when the number of monitoring object status change events exceeds a maximum value (which is 100).

The setting for whether such JP1 warning-level events are to be issued is enabled for a new installation. If the setting was disabled under an old version of JP1/IM - Manager or JP1/IM - Central Scope, it remains disabled. You should change the setting as appropriate to your operation.

To specify the settings for the maximum number of status change events:

  1. Terminate JP1/IM - Manager.

  2. Execute the jbssetcnf command using one of the following files as the argument as appropriate:

    If JP1 events are to be issued when the maximum number of status change events exceeds the maximum value: evhist_warn_event_on.conf

    If JP1 events are not to be issued when the maximum number of status change events exceeds the maximum value: evhist_warn_event_off.conf

    When you execute the jbssetcnf command, the setting is applied to the JP1 common definition information.

    For details about the jbssetcnf command, see the Job Management Partner 1/Base User's Guide.

    About the setting in the file:

    For details about the setting in the file, see Settings file for the maximum number of status change events (evhist_warn_event_xxx.conf) in 2. Definition Files in the manual Job Management Partner 1/Integrated Management - Manager Command and Definition File Reference.

  3. Start JP1/IM - Manager.