ctmstsstop command cannot be executed. reason code=aa....aa-bb....bb
Table 19-25 List of reason codes displayed in KFCT73309-E
| Reason code | Cause | Action |
|---|---|---|
| 1 | Memory is insufficient. | Revise the memory size |
| 3 | The shared memory used for operation statistics cannot be accessed. | Contact maintenance personnel. |
| 5 | The specified environment variable CTMSPOOL is invalid. | Revise the value specified in the environment variable CTMSPOOL. If the environment CTMSPOOL is not specified, revise the value specified in the environment variable CTMDIR. |
| 8 | The path specified in the environment variable CTMSPOOL is too long. | Check whether the length of the path exceeds 1,023 bytes and, if necessary, revise it. |
| 10 | An attempted exclusive control has failed. | Contact maintenance personnel. |
| 13 | An error occurred in the system call. | Check the message displayed before this message, and then contact maintenance personnel. |
| 15 | An error occurred in the internal processing. | Contact maintenance personnel. |
| 16 | An attempt to acquire the IP address has failed. | Contact maintenance personnel. |
| 17 | The CTM daemon of the relevant CTM identifier is not online or the statistical information service is not running in the CTM node. | Confirm that the CTM daemon is running. |
| 18 | The exclusive control between processes has failed. | Contact maintenance personnel. |
| 22 | The ctmstsstart command is not yet executed. | Execute the ctmstsstart command, and then execute the ctmstsstop command. |
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.