uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KFCT70711-E
the error occurred while finalizing CTM for J2EE server. kind=aa....aa detail=bb....bb inter=cc....cc.
- aa....aa: Error type
bb....bb: Maintenance information 1
cc....cc: Maintenance information 2
- Description
- An error occurred in the termination process of the CTM functionality for the J2EE server.
- The termination process of CTM will be interrupted, but the process of stopping the J2EE server continues.
- Action
- Take action based on the error type described in aa....aa, and then restart the J2EE server. The error type described in aa....aa and the corresponding actions are as follows:
- NOT_INITIALIZED
- The initialization of CTM is not complete. Check whether an error occurred during the CTM initialization process.
- If an error occurred during the initialization process, remove the error.
- In cases other than above
- An error occurred in the internal processing.
- Acquire kind (aa....aa), detail (bb....bb), and inter (cc....cc), and then contact maintenance personnel.
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.