uCosminexus Application Server, Messages
the error occurred while initializing CTM for J2EE server. kind=aa....aa detail=bb....bb inter=cc....cc.
Table 19-7 List of error types described in KFCT70710-E
| Cause of error | Cause | Action |
|---|---|---|
| LOAD_LIBRARY | An attempt to read the library has failed. | Check whether the library path environment variables are set correctly and, if necessary, revise them. |
| ENVIRON | An attempt to acquire the environment variables has failed. | Check whether the environment variables CTMDIR and CTMSPOOL are set correctly and, if necessary, revise them. |
| COMMUNICATION | An error occurred in the communication process. | Check whether the Cosminexus TPBroker environment and properties are set correctly and, if necessary, revise them. |
| SH_MEM | An attempt to access shared memory has failed. | Check whether the environment variables CTMDIR and CTMSPOOL are set correctly and, if necessary, revise them. In addition, check whether the CTMSPOOL directory exists, whether the library or directory under CTMSPOOL is deleted or changed, and whether the permissions have been changed and, if necessary, revise them. |
| MEMORY | The memory is insufficient. | Terminate the unnecessary processes. |
| Others | An error occurred in the internal processing. | Acquire kind (aa....aa), detail (bb....bb), and inter (cc....cc), and then contact maintenance personnel. |
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.