Job Management Partner 1/Performance Management User's Guide
To change the maximum number of records for event data to store in the Store database, use the Services window in PFM - Web Console.
- Note:
- You need to have Administrator user permissions to use the Services window.
To modify the maximum number of records for alarm event data:
- Log on to PFM - Web Console from the browser of the monitoring console.
You need to log on as a user with Administrator user permissions.
The main window of PFM - Web Console appears.
- In the navigation frame of main window, select the Services tab.
The Services window appears.
- In the navigation frame of the Services window, expand the hierarchy under the PFM - Manager folder.
Services provided by PFM - Manager are displayed. The name of each service is represented by the service ID.
- Select the Master Store service.
The name of the Master Store service begins with PS or is <Master Store>.
The selected Master Store service is marked with a checkmark.
- In the method frame, select Properties.
The Properties window of the Master Store service is displayed with the properties shown hierarchically.
- Select the Retention node.
At the bottom of the information frame, the properties of the Retention node are displayed.
Figure 4-6 Example settings for maximum number of records (event data)
Modify the property settings. The following table gives a description and setting for the property.
Table 4-20 Description and settings for each property
Record type Property name Settings PA record type Product Alarm - PA Sets the maximum number of records to store for event data. You can specify a numerical value from 0 to 2,147,483,647. - Click the OK button.
Your settings are enabled.
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.