Job Management Partner 1/Integrated Management - Manager Overview and System Design Guide
- Organization of this subsection
- (1) Restrictions on connecting to JP1/IM - Central Console 07-00 or 07-01 from JP1/IM - View 09-00
- (2) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Console)
- (3) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Scope)
(1) Restrictions on connecting to JP1/IM - Central Console 07-00 or 07-01 from JP1/IM - View 09-00
Table H-13 Restrictions on connecting to JP1/IM - Central Console 07-00 or 07-01 from JP1/IM - View 09-00
JP1/IM-CC
versionRestrictions# 1 to 5 6 to 17 18 19 to 36 07-00 Y Y -- Y 07-01 -- Y -- Y
- Legend:
- JP1/IM-CC: JP1/IM - Central Console
- Y: Applicable
- --: Not applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-14 List of restrictions
No. Details 1 A condition group cannot be specified when defining a filter. 2 You cannot set multiple view filters or use the Filter name list box on the Monitor Events page of the Event Console window. 3 The following command is unavailable in the View menu of the Event Console window:
- View List of Filters
4 The following window cannot be accessed:
- Event Acquisition Conditions List window
5 You cannot set multiple conditions separated by commas in the Source host, User name, or Object name box in the Event Acquisition Settings window. 6 The following commands are unavailable in the View menu or Options menu of the Event Console window:
- Function-Status Notification Return
- Display Related Event List
7 The Summary status column does not appear in the Event Console window. 8 You cannot set Display most significant status in the Preferences window. 9 You cannot set Status monitoring in the Action Parameter Definitions window. 10 You cannot set Suppress or Delay monitoring in the Action Parameter Detailed Definitions window. 11 You cannot perform the following operations in the Action Log window:
- View the Action serial number or Delay fields.
- Click the Cancel Action, Re-execute, or Suppress Trigger Details buttons.
12 You cannot perform the following operations in the Action Log Details window when opened from the Action Log window:
- View the Action serial number, Delay, Starting time, or Inserted time fields.
- Click the Cancel Action or Re-execute button.
13 You cannot perform the following operations on the General page of the System Environment Settings window:
- Click the Editing list button.
- Select an item in the Event acquisition conditions drop-down list.
14 You cannot set Filter name or Filter ID in the Event Acquisition Settings window. 15 You cannot perform the following operations in the Action Log Details window when opened from the List of Action Results window:
- View the Action serial number, Event arrival time, Delay, Starting time, or Inserted time fields.
- Click the Cancel Action button.
16 You cannot perform the following operations in the List of Action Results window:
- View the Action serial number, Event arrival time, or Delay fields.
- Click the Cancel Action, Suppress Trigger Details,
,
,
, or Target Event Search buttons.
17 You cannot set an action whose parameters exceed 1,023 bytes in length in the Action Parameter Detailed Definitions window. 18 You cannot set an action whose parameters exceed 1,040 bytes in length in the Action Parameter Detailed Definitions window. 19 You cannot change the response status on the Search Events page of the Event Console window. 20 You cannot perform the following operations during an event search:
Search results are not listed sequentially.
- Access another window.
- Cancel the event search.
21 Type and Action type do not appear in the Display items & order area of the Preferences window. 22 You cannot set Lines of execution results to display in the Preferences window. 23 The Rule Log Details button does not appear in the List of Action Results window. 24 The Type column does not appear in the Action Log window. Also, Type is not shown in the Log area of the Action Log Details window. 25 The Type column does not appear in the Action Parameter Definitions window. Also, Type is not shown in the Action Definition area of the Action Parameter Detailed Definitions window. 26 The Type column does not appear in event listings in the Event Console window. 27 You cannot execute commands exceeding 1,024 bytes in length in the Execute Command window. 28 The Rule Log Details button does not appear in the following windows:
- Action Log window
- Action Log Details window
29 The Type column does not appear in the List of Action Results window. 30 You cannot specify exclusion conditions in the following windows (the Exclusion-conditions group area is unavailable):
You cannot specify common exclusion conditions in the following windows (the Common exclusion-conditions groups area is unavailable):
- Settings for View Filter window
- Severe Event Definitions window
- Detailed Settings for Event Receiver Filter window
- Event Search Conditions window
- Event Acquisition Settings window
- System Environment Settings window
- Event Acquisition Conditions List window
31 The event display start-time specification area does not appear on the Monitor Events and Severe Events pages. 32 The Display range area does not appear on the Monitor Events and Severe Events pages. 33 The following items related to the specified display event period feature do not appear:
- Use specified display event period check box on the Monitor Events page
- Use specified display event period check box on the Severe Events page
- Use specified display event period menu in the Event Console window
- Specified display event period area in the Preferences window
34
- The Action Parameter Detailed Definitions window (for compatibility) is displayed instead of the Action Parameter Detailed Definitions window.
- Action names are not displayed in the Action Parameter Definition window.
35
- You cannot view or set memo entries.
- Memo does not appear in the Display items & order area of the Preferences window.
- The Memo area does not appear in the Event Details window.
- You cannot set memo entries in the Settings for View Filter window.
- You cannot set memo entries in the Event Search Conditions window.
36 You cannot specify a response status in the following windows:
- Settings for View Filter window
- Event Search Conditions window
(2) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Console)
Table H-15 Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Console)
JP1/IM - View
versionsRestrictions# 1 to 6 7 to 19 20 to 22 23 to 44 07-00, 07-01 Y Y Y Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-16 List of restrictions
No. Details 1 You cannot select the Read From Selected Event option in the Event Acquisition Settings window. 2 View filters set in JP1/IM - View 08-01 or later cannot be used.
- View filters
View filters set in JP1/IM - View 08-01 or later cannot be used.
- Severe events filter and event receiver filter
Defined filters cannot be applied to the manager.
- Event search conditions
Event search conditions set in JP1/IM - View 08-01 or later cannot be used.
3 You cannot set multiple view filters or use the Filter name list box on the Monitor Events page of the Event Console window. 4 You cannot set Search direction in the Event Search Conditions window. Also, you cannot click Current Time for Start timeframe, End timeframe, Registered timeframe, or Arrived timeframe. 5 You cannot set multiple conditions separated by commas in the Source host, User name, or Object name box in the Event Acquisition Settings window. 6 You cannot select Regular expression in the Event Acquisition Settings window. 7 The following commands are unavailable in the View menu and Options menu of the Event Console window:
- Function-Status Notification Return
- Display Related Event List
8 The Summary status column does not appear in the Event Console window. 9 You cannot open the Event Acquisition Conditions List window. 10 You cannot set Display most significant status in the Preferences window. 11 You cannot open the Related Events window. 12 You cannot set Status monitoring in the Action Parameter Definitions window. 13 You cannot set Suppress or Delay monitoring in the Action Parameter Detailed Definitions window. 14 You cannot perform the following operations in the Action Log window:
- View the Action serial number or Delay fields.
- Click the Update, Cancel Action, Suppress Trigger Details, or Re-execute buttons.
15 You cannot perform the following operations in the Action Log Details window:
- View the Action serial number, Event arrival time, Delay, Starting time, or Inserted time fields.
- Click the Cancel Action or Re-execute button.
16 You cannot set Filter name or Filter ID in the Event Acquisition Settings window. 17 You cannot perform the following operations on the General page of the System Environment Settings window:
- Click Editing list.
- Select an item in the Event acquisition conditions drop-down list.
18 You cannot define and switch between multiple event acquisition filters. 19 You cannot perform the following operations in the List of Action Results window:
- View the Action serial number, Event arrival time, or Delay fields.
- Click the Cancel Action, Suppress Trigger Details,
,
,
, or Target Event Search buttons.
20 You cannot change the response status on the Search Events page of the Event Console window. 21 You cannot view event guide information in the Event Details window. 22 You cannot perform the following operations during an event search:
Search results are not listed sequentially.
- Access another window.
- Cancel the event search.
23 You cannot display icons in the Action column of the Event Console window. 24 The Type and Action type columns do not appear in event listings in the Event Console window. 25 Correlation source events cannot be displayed because no window is provided for displaying them. 26 Type and Action type do not appear in the Display items & order area of the Preferences window. 27 You cannot set Lines of execution results to display in the Preferences window. 28 You cannot sort the execution results displayed in the Execute Command window. 29 You cannot execute commands exceeding 1,024 bytes in length in the Execute Command window. 30 The Rule Log Details button does not appear in the following windows:
- Action Log window
- Action Log Details window
31 The Type column does not appear in the Action Log window. Also, Type is not shown in the Log area of the Action Log Details window. 32 The Type column does not appear in the Action Parameter Definitions window. Also, Type is not shown in the Action Definition area of the Action Parameter Detailed Definitions window. 33 You cannot specify <RULE> in the Action field of the Action Parameter Definitions window. 34 You cannot open the Action Parameter Definitions window when a rule startup request to JP1/IM - Rule Operation is defined in the automated action definition file (actdef.conf). 35 The Rule Log Details button does not appear in the List of Action Results window. 36 The Type column does not appear in the List of Action Results window. 37 The Edit menu does not appear in the Event Console window. 38
- You cannot display or modify the following filters if exclusion conditions are set for the filter:
- Event acquisition filter
- Event receiver filter
- Severe event filter
- You cannot display or modify an event acquisition filter if common exclusion conditions are set for the filter.
- You cannot display or modify the following filters if a conditions group with an Action type specified is defined for the filter:
- Event receiver filter
- Severe event filter
39 The event display start-time specification area does not appear on the Monitor Events and Severe Events pages. 40 The Display range: area does not appear on the Monitor Events and Severe Events pages. 41 The following items related to the specified display event period feature do not appear:
- Use specified display event period check box on the Monitor Events page
- Use specified display event period check box on the Severe Events page
- Use specified display event period menu in the Event Console window
- Specified display event period area in the Preferences window
42
- The Action Parameter Detailed Definitions window (for compatibility) is displayed instead of the Action Parameter Detailed Definitions window.
- Action names are not displayed in the Action Parameter Definition window.
43
- You cannot view or set memo entries.
- Memo does not appear in the Display items & order area of the Preferences window.
- The Memo area does not appear in the Event Details window.
- You cannot set memo entries in the Settings for View Filter window.
- You cannot set memo entries in the Event Search Conditions window.
44 You cannot specify a response status in the following windows:
- Settings for View Filter window
- Event Search Conditions window
(3) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Scope)
Table H-17 Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 07-00 or 07-01 (when using the Central Scope)
JP1/IM - View
versionsRestrictions# 1 to 11 07-00, 07-01 Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-18 List of restrictions
No. Details 1 The following restrictions apply when using the Monitoring Tree window:
- JP1/IM - View functionality is limited to that provided by version 07-00 (you cannot use map view, for example).
- When five or more status change conditions are set, only the first four are displayed.
- The Condition list box does not appear in the Individual conditions area of the Status-Change Condition Settings window.
2 The following restriction applies when using the Monitoring Tree window:
- All login users operate under the JP1_Console_User permission (for details on the range of operations available to users with JP1_Console_User permission, see E.2 Operating permissions required for system monitoring using the Central Scope).
3 Restrictions apply when using the Monitoring Tree (Editing) window and the Visual Monitoring (Editing) window#.
Because you cannot log in to the server, the following operations are unavailable:
- Auto-generate a monitoring tree.
- Acquire existing monitoring tree settings from the server.
- Apply edited monitoring tree settings to the server.
- Acquire the existing settings of the Visual Monitoring window from the server.
- Apply the settings edited in the Visual Monitoring window to the server.
- Acquire the latest data for the common condition of a status change condition.
4 The following restriction applies when using the Monitoring Tree window:
- The icon and monitoring node type are not displayed for the system-monitoring object (Cosminexus) added in version 08-01.
5 The following restriction applies when using the Monitoring Tree window:
- The icon and monitoring node type are not displayed for the system-monitoring objects (HiRDB and System Manager) added in version 08-01.
6 The following restrictions apply when using the Monitoring Tree window:
- You cannot view or modify a status change condition set for a monitoring group. However, monitoring of the status change condition will take place.
- The icon indicating that a status change condition is set for a monitoring group is not displayed in the Monitoring Tree window.
7 Monitoring range settings for monitoring trees have no effect (the JP1 resource group does not appear in the Properties window). 8 You cannot use the same event attribute name for more than one individual condition. 9 The following restrictions apply when using the same event attribute name for more than one individual condition:
- When the same event attribute name is shared by more than one individual condition in a status change condition, only the first individual condition is displayed in the Monitoring Tree window.
- Access to the Monitoring Tree window is subject to view permission only. You cannot edit individual conditions or other settings.
- In the Monitoring Tree (Editing) window, you cannot specify the same event attribute name in more than one individual condition.
10 The following restriction applies to the Monitoring Tree window:
- Visual Icon are not displayed in the Monitoring Tree window (normal icons are displayed instead).
11 The following restriction applies to the Monitoring Tree window:
The icon and monitoring node type are not displayed for the system-monitoring object (NNMi).#: For details on dealing with these restrictions, see 9.5(10) Actions to take when an earlier version of JP1/IM - Central Scope or JP1/IM - View is being used in the Job Management Partner 1/Integrated Management - Manager Administration Guide.
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.