Job Management Partner 1/Integrated Management - Manager Overview and System Design Guide
- Organization of this subsection
- (1) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Console)
- (2) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Scope)
- (3) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using IM Configuration Management)
- (4) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Console)
- (5) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Scope)
- (6) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using IM Configuration Management)
(1) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Console)
Table H-1 Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Console)
JP1/IM - Manager version Restrictions# 1 to 8 08-01 Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-2 List of restrictions
No. Details 1 You cannot specify exclusion conditions in the following windows (the Exclusion-conditions group area is unavailable):
You cannot specify common exclusion conditions in the following windows (the Common exclusion-conditions groups area is unavailable):
- Settings for View Filter window
- Severe Event Definitions window
- Detailed Settings for Event Receiver Filter window
- Event Search Conditions window
- Event Acquisition Settings window
- System Environment Settings window
- Event Acquisition Conditions List window
2 The event display start-time specification area does not appear on the Monitor Events and Severe Events pages. 3 The Display range: area does not appear on the Monitor Events and Severe Events pages. 4 The following items related to the specified display event period feature do not appear:
- Use specified display event period check box on the Monitor Events page
- Use specified display event period check box on the Severe Events page
- Use specified display event period menu in the Event Console window
- Specified display event period area in the Preferences window
5
- The Action Parameter Detailed Definitions window (for compatibility) is displayed instead of the Action Parameter Detailed Definitions window.
- Action names are not displayed in the Action Parameter Definition window.
6
- You cannot view or set memo entries.
- Memo does not appear in the Display items & order area of the Preferences window.
- The Memo area does not appear in the Event Details window.
- You cannot set memo entries in the Settings for View Filter window.
- You cannot set memo entries in the Event Search Conditions window.
7 You cannot specify a response status in the following windows:
- Settings for View Filter window
- Event Search Conditions window
8 Correlation failure events are displayed as correlation approval events in the following windows:
- Event Console window
- Related Events window
(2) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Scope)
Table H-3 Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using the Central Scope)
JP1/IM - Manager version Restrictions# 1 to 2 08-01 Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-4 List of restrictions
No. Details 1
- The Visual Icon display option is unavailable in the View menu of the Monitoring Tree window.
- The Visual Icon display option is unavailable in the Options menu of the Monitoring Tree (editing) window.
- You cannot set Visual Icon on the General page of the Properties window.
2 The following restrictions apply:
- When creating a monitoring object, you cannot select the system-monitoring objects Node Monitoring (NNMi) and NNMi Monitoring added in version 09-00. These system-monitoring objects will not appear in the Monitoring node type drop-down list in the Create New Monitoring Node window.
- You cannot use common conditions associated with system-monitoring objects (NNMi) added in version 09-00. These common conditions will not appear in the Common Condition Settings area in the Common Condition Settings window.
- You cannot use the Agent Monitoring (PFM) system-monitoring object or associated common conditions to monitor JP1/PFM system events.
(3) Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using IM Configuration Management)
Table H-5 Restrictions on connecting to JP1/IM - Manager 08-01 from JP1/IM - View 09-00 (when using IM Configuration Management)
JP1/IM - Manager version Restrictions# 1 08-01 Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-6 List of restrictions
No. Details 1 You cannot connect to JP1/IM - Manager from IM Configuration Management - View.
(4) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Console)
Table H-7 Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Console)
JP1/IM - View version Restrictions# 1 to 10 08-01 Y
- Legend:
- Y: Applicable
#: The restriction number corresponds to the number in the following table.
Table H-8 List of restrictions
No. Details 1 The Edit menu does not appear in the Event Console window. 2
- You cannot display or modify the following filters if exclusion conditions are set for the filter:
- Event acquisition filter
- Event receiver filter
- Severe event filter
- You cannot display or modify an event acquisition filter if common exclusion conditions are set for the filter.
3 The event display start-time specification area does not appear on the Monitor Events and Severe Events pages. 4 The Display range: area does not appear on the Monitor Events and Severe Events pages. 5 The following items related to the specified display event period feature do not appear:
- Use specified display event period check box on the Monitor Events page
- Use specified display event period check box on the Severe Events page
- Use specified display event period menu in the Event Console window
- Specified display event period area in the Preferences window
6 The following restrictions apply when using an action definition file from version 08-01 or earlier of JP1/IM - Manager:
- The Action Parameter Detailed Definitions window from version 08-01 is displayed.
- Action names are not displayed in the Action Parameter Definition window.
7 The following restriction applies when using an action definition file from version 09-00 of JP1/IM - Manager:
- You cannot display the Action Parameter Detailed Definitions window.
8
- You cannot view or set memo entries.
- Memo does not appear in the Display items & order area of the Preferences window.
- The Memo area does not appear in the Event Details window.
- You cannot set memo entries in the Settings for View Filter window.
- You cannot set memo entries in the Event Search Conditions window.
9 You cannot specify a response status in the following windows:
- Settings for View Filter window
- Event Search Conditions window
10 Correlation failure events are displayed as correlation approval events in the following windows:
- Event Console window
- Related Events window
(5) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Scope)
Table H-9 Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using the Central Scope)
JP1/IM - View version Restrictions# 1 to 3 08-01 Y
- Legend:
- Y: Applicable
#: The restriction numbers correspond to the numbers in the following table.
Table H-10 List of restrictions
No. Details 1 The following restriction applies to the Monitoring Tree window:
- All login users operate under the JP1_Console_User permission (for details on the range of operations available to users with JP1_Console_User permission, see E.2 Operating permissions required for system monitoring using the Central Scope).
2 Restrictions apply when using the Monitoring Tree (Editing) window and the Visual Monitoring (Editing) window#.
Because you cannot log in to the server, the following operations are unavailable:
- Auto-generate a monitoring tree.
- Acquire existing monitoring tree settings from the server.
- Apply the edited monitoring tree settings to the server.
- Acquire the existing settings of the Visual Monitoring window from the server.
- Apply the settings edited in the Visual Monitoring window to the server.
- Acquire the latest data for the common condition of a status change condition.
3 The following restriction applies to the Monitoring Tree window:
- The icon and monitoring node type are not displayed for the system-monitoring object (NNMi).
#: For details on dealing with these restrictions, see 9.5(10) Actions to take when an earlier version of JP1/IM - Central Scope or JP1/IM - View is being used in the Job Management Partner 1/Integrated Management - Manager Administration Guide.
(6) Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using IM Configuration Management)
Table H-11 Restrictions on connecting to JP1/IM - Manager 09-00 from JP1/IM - View 08-01 (when using IM Configuration Management)
JP1/IM - Manager version Restrictions# 1 08-01 Y
- Legend:
- Y: Applicable
#: The restriction number corresponds to the number in the following table.
Table H-12 List of restrictions
No. Details 1 You cannot connect to IM Configuration Management.
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.