Nonstop Database, HiRDB Version 9 System Operation Guide

[Contents][Index][Back][Next]

29.3 Configuring HiRDB

The following is the procedure for configuring HiRDB to use HiRDB expansion units.

Procedure
  1. Configure HiRDB (all base units), excluding HiRDB expansion units.
    For details, see 29.3.1 Configuring a base unit.
  2. To configure a HiRDB expansion unit, use the pdstart command to start the HiRDB configured in step 1. If you choose not to configure a HiRDB expansion unit at this point, proceed to step 5.
  3. Configure a HiRDB expansion unit.
    For details, see 29.3.2 Configuring a HiRDB expansion unit.
  4. Use the pdstop command to terminate HiRDB, except for the HiRDB expansion unit started in step 2.
  5. This completes configuration of a HiRDB system.
 
Note
  • The maximum combined total number of base units and HiRDB expansion units that can be configured is 64.
  • Because the environment for a HiRDB expansion unit can be set up before actual startup, there is no need to configure a HiRDB expansion unit together with a base unit during initial system configuration. Note however, that HiRDB expansion units must be defined beforehand in the system common definition.
Organization of this section
29.3.1 Configuring a base unit
29.3.2 Configuring a HiRDB expansion unit