OpenTP1 Version 7 Tester and UAP Trace User's Guide
(1) Online tester command does not terminate normally
Take one of the following actions, then re-enter the command:
- If usage of the online tester is not specified in the system service configuration definition, terminate OpenTP1, configure the online tester in the definition (specify Y in the uto_conf operand), then restart OpenTP1.
- If an option or command argument is incorrectly specified, correct the option or command argument.
- If a file required for command execution does not exist, create the file. Or, if the existing file cannot be used because access is prohibited, change the access authority.
(2) UAP trace information not collected
(a) No UAP trace information collected at all
If zero is specified as the maximum size of the trace file (max_trace_file_size operand) in the tester service definition, terminate OpenTP1, specify 1 or a higher value, then restart OpenTP1.
(b) Trace information not collected for a specific UAP
Take one of the following actions:
- If the UAP is not specified as a test UAP in the user service definition, terminate the UAP, correct the definition (specify target in the test_mode operand), then restart the UAP.
- If zero is specified as the maximum number of UAP traces (uap_trace_max operand) in the user service definition, terminate the UAP, specify 1 or a higher value, then restart the UAP.
(c) Some trace information missing
Take one of the following actions:
- If the trace file is full, back up to another file, then delete the full file.
- If the online tester shut down during UAP execution, restart the online tester, then re-execute the UAP.
- If the UAP detected an abnormality and immediately shut down without collecting the core file, modify the program so that the core file can be collected, then re-execute the UAP.
(3) Send messages not collected
(a) No send messages collected at all
If zero is specified as the maximum size of the MCF send message file (max_message_file_size operand) in the tester service definition, terminate OpenTP1, specify 1 or a higher value, then restart OpenTP1.
(b) Send messages not collected for a specific UAP
If the UAP is not specified as a test UAP in the user service definition, terminate the UAP, correct the definition (specify target in the test_mode operand), then restart the UAP.
(c) Some send messages missing
If the MCF send message file is full, back up to another file, then delete the full file.
(4) No send data collected for interactive service requests.
(a) No send data collected at all
If N is specified for send data output (test_xatmi_send_file operand) in the user service definition, terminate the UAP, specify Y, then restart the UAP.