OpenTP1 Version 7 Messages

[Contents][Index][Back][Next]

KFCA00307-E (E)

insufficient file descriptor for RPC. local pid=aaaa, local process port number=bbbb

Socket file descriptors were insufficient for this process to perform inter-process communication with the system server or user server.
aaaa: Process ID of the process with insufficient socket
bbbb: Receiving port number (listen port number) of the process for which socket descriptors were insufficient
S: Outputs the KFCA00105-E message with abort code r320002 or r230091, and terminates the process abnormally.
O: Check and correct the values of the max_socket_descriptors and max_open_fds definitions in the system operation environment. Then, restart the process. If the system has stopped, restart it. For examples of errors in which a message is output and the procedure for finding the reason they occurred, see the manual OpenTP1 Operation.