OpenTP1 Version 7 Messages
KFCA00307-E (E)
insufficient file descriptor for RPC. local pid=aaaa, local process port number=bbbb
- Socket file descriptors were insufficient for this process to perform inter-process communication with the system server or user server.
- aaaa: Process ID of the process with insufficient socket
- bbbb: Receiving port number (listen port number) of the process for which socket descriptors were insufficient
- S: Outputs the KFCA00105-E message with abort code r320002 or r230091, and terminates the process abnormally.
- O: Check and correct the values of the max_socket_descriptors and max_open_fds definitions in the system operation environment. Then, restart the process. If the system has stopped, restart it. For examples of errors in which a message is output and the procedure for finding the reason they occurred, see the manual OpenTP1 Operation.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.