OpenTP1 Version 7 Operation

[Contents][Index][Back][Next]

mcftonln (Start accepting server-type connection establishment requests)

Format

mcftonln -s MCF-communication-process-identifier

Function

The mcftonln command starts acceptance of requests to establish a server-type connection.

Option

-s MCF-communication-process-identifier~<hexadecimal> ((01-ef))

Specifies an MCF communication process identifier.

No more than one MCF communication process identifier can be specified.

Output messages

Message ID Description Output destination
KFCA10350-I The mcftonln command has been entered. Standard output
KFCA10351-E MCF startup processing is underway. Standard error output
KFCA10352-E MCF termination processing is underway. Standard error output
KFCA10353-W Input format is invalid. Standard error output
KFCA10354-E Memory is inadequate. Standard error output
KFCA10355-W Specification of an argument is invalid. Standard error output
KFCA10356-E Timeout occurred during a process. Standard error output
KFCA10357-E Timeout occurred in the MCF. Standard error output
KFCA10358-E Error occurred in an internal function. Standard error output
KFCA10359-W Response to mcftonln command input source failed. Message log file
KFCA10370-I The mcftonln command was accepted normally. Standard output
KFCA10372-E The mcftonln command terminated abnormally. Standard error output
KFCA10380-E Retrieval of a remote process failed. Standard error output
KFCA10391-E The mcftonln command is not supported. Standard error output
KFCA10559-I Help message Standard output
KFCA16402-E RPC error occurred. Standard error output

In addition to the messages listed above, other messages might be output depending on the protocol being used. For details, see the manual for each protocol.